CAN Bus Termination
Introduction
A CAN bus must have a 120 Ω termination at each of its two ends. The two resistors are in parallel, so the correct resistance between CAN-H and CAN-L is 60 Ω.
Without both resistors, the CAN messages can get corrupted. The drone can seem to work normally on the ground, but lose CAN messages in flight. For this reason, the termination must always be checked after assembly.
Bus topology
The termination must be ON only on the two devices at the ends of the bus. All devices in between must have their termination OFF.

Skynode
Skynode S, Skynode X
Fixed 120 Ω, always ON. The Skynode must be at one end of the bus.
Skynode N
CAN Termination switch. Set it to ON if the Skynode is at one end of the bus, and to OFF if it is in the middle of the bus.
Other CAN devices
Check the datasheet of your Auterion CAN product for information about its termination.
Check the termination with a multimeter
The termination can be checked with a multimeter by measuring the resistance between CAN-H and CAN-L.
The vehicle must be completely powered off. Disconnect the battery before the measurement. When the bus is powered, the multimeter reading is not valid.
Disconnect the battery. Leave all CAN devices connected to the bus.
Set the multimeter to resistance measurement (Ω).
Measure between the CAN-H and CAN-L wires at any free CAN connector of the bus. On a standard 4-pin JST-GH CAN connector, CAN-H is pin 2 and CAN-L is pin 3.
Compare the reading with the table below.
More than 60 Ω
A termination is missing
~60 Ω
Correct
Less than 60 Ω
Too many terminations
Repeat the check after every change of the CAN wiring, and after adding, removing or replacing a CAN device.
Last updated